-40%
K24 10-120L / MIN turbo electronic flowmeter Diesel fuel Methanol Urea Precision
$ 15.77
- Description
- Size Guide
Description
K24 10-120L / MIN turbo electronic flowmeter Diesel fuel Methanol Urea PrecisionK24 internal thread
Flowmeter manual
Outline
The modular design of the product control panel , with a full-featured , simple structure, convenient operation .
Can be widely used in petroleum, chemical, pharmaceutical, transportation, food to be industrial and commercial .
I.
Technical Parameters
Media
Diesel oil, urea, kerosene, chemicals , gasoline
Import and export
1"
Measurement accuracy
± 1%
Repeatability
± 0.5%
Maximum working pressure
20BAR
Operating Voltage
3V(2*AA,but no battery inclued)
Standby time
2
Year
Flow Range
10-120L / MIN
Single counting
0.00-9999.9
The total cumulative number
0.00-999999.9
Unit of Measure
Liter
/ L
, Gallon
/ GAL
, Pint
/ PTS
, Quart
/ QTS
Single measurement cleared
RESET
II.
Units of measurement settings
In standby mode , or raise the amount of the current display state , press
RESET + MENU
Bond
2
Seconds. Entering the unit conversion settings , such as screen as significant
L
Press
RESET
Button , followed by
LTR
→
GAL
→
PT
→
QT
→
L
Select the unit of measurement , while the cumulative amount raised after the display in accordance with the current measurement units conversion. Press
MENU
Bond
1
Seconds to exit the unit conversion settings.
III.
Can reset the cumulative amount cleared filling
Long press
RESET
Key,
LCD
Fit as significant , depending on the end after waiting the full screen display , release
RESET
Button , then you can reset the cumulative amount of the filling amount with the current filling cleared .
Five .
Error coefficient and the total cumulative inquiry
In standby mode, press
MENU + RESET
Key,
LCD
The row of numbers as significant error coefficient , the lower the total cumulative significantly depending on traffic.
VI. Calibration error coefficient
In standby mode , or raise the amount of the current display status , press
MENU
Button
3
Seconds to enter the calibration coefficient error state. Displays
Cal USE
Press
MENU
Button to select the number, then press
RESET
Key , digitally adjusted. Standard Coefficient
1.000
, Transferred
1.100
, A difference
10L
The higher the number , the less oil , the smaller the number , the more oil. After adjustment Press
MENU
Key to perform exit.
Seven. Care and Maintenance
When the battery voltage is too low ,
LCD
Battery symbol appears on the display screen to remind users to replace the battery.
Battery life is too short can cause the battery during operation due to leakage caused by damage to the meter. This meter is designed standby life is about
2
Years, but recommends that customers each year to replace the battery . Customers are advised to check once each year battery electrode , should be subject to rust promptly removed. When long time without using the meter , the battery should be out .
Instruction Manual for K24 Flow Meter
Introduction
The control panel of K 24 Flow meter adopts the concept of modular design, with features of complete function, simple construction, easy operation, etc, which is widely used in petroleum, chemistry, medicine, traffic, food and commercial industry.
1. TECHNICAL DATA
Medium
Diesel, urea, kerosene,chemicals, gasoline
outlet&inlet size
1"
measuring accuracy
±1%
repeatability
±0.5%
Max working pressure
20BAR
working voltage
2.3-3.3V
standby time
2 years
flow-rate range
10-120L/MIN
single count
0.00-999.9
total count
0.00-999999.9
measurement unit
L,GAL,PTS,QTS
single measurement reset
RESET
2. SET OF MEASUREMENT UNIT
Under the state of standby or current charging display, press the button of MENU and RESET at the same time for 5 seconds. Enter the setting of unit conversion and press the RESET button, choose the measurement unit in turn according to the order of LTR→GAL→PT→QT→LTR, meanwhile the accumulated charging quantity will be displayed based on the conversion of the current measurement unit conversion. Then press the MENU button for 3 seconds to quit the unit conversion setting.
3. Error Coefficient Calibration
Under the state of standby or current charging display, press the button of MENU for 3 seconds, entering the state of error coefficient calibration. Meanwhile when the first digital blinking displays, press the MENU button, then numeric shift (blinking digital displacement), press the RESET button, modify the current blinking figure, from 0 to 9 in turn, then back to 0. The oil pump capacity is less when the digital is increased; vice versa. Press the button MENU for 3 seconds to quit the error coefficient calibration. Back to the state of current charging quantity,and display it as reset. After the error coefficient calibration, demarcate it when there is new measuring pulse input. The range of the error coefficient calibration is from 0.1000 to 9.9999. Press the button of MENU and RESET at the same time to check the coefficient and total accumulated figure.
4. EXAMPLE OF Error Coefficient Adjustment
When the original figure is 1.000, it will display as 100 L oil, the actual oil pump capacity is also 100 L. In case the user wants to reduce 2 L oil, then press the button of MENU for 3 seconds, adjust it to 1.020 according to the Error coefficient Calibration. Then the oil pump capacity will be 98 L. For 96 L, adjust it to 1.040; visa versa.
1) Battery Low Prompt
When the voltage of battery is between 2.2 v to 2.4 v, it will display as LBAT, to remind the user to replace the battery.
5. Maintenance and Preservation
This flow meter needs the battery with life span of at least 9,000 hours (1 year) as the power supply. The short battery life will lead to the battery leakage during working and result in the damage of the flow meter. The standby life of this flow meter is designed as 2 years. Battery replacement every one year is recommended. In case the LCD display becomes dim or the Lbat occurs, it is time to replace the battery. We recommend the users to check the Battery electrode to clear the rusting in case. Take out the battery if the flow meter is not used for a long time.
come with
1x k24 flowmeter
shipping & payment
* you will get it in 10-20 working days by standard airmail shipping from Hong Kong Post.
* Only paypal accapted.it is fast ,easy & safe way.
Contact us:
* If you have any request please don't hesitate to contact us at first time,we will help you and solve your issue within 24 hours.
* All emails will be answered within 1 business day. If you do not receive our reply, please kindly re-sent your email and we will reply you as soon as possible.
* Warranty services are for replacements only,any problem please kindly email us frist,we will accept your advise & request.
DO NOT DUPLICATE OR COPY! Template Made By: ©
InkFrog.com
Auction Templates, Logos, Store fronts and more!