-40%

K24 10-120L / MIN turbo electronic flowmeter Diesel fuel Methanol Urea Precision

$ 15.77

Availability: 45 in stock
  • Country/Region of Manufacture: China
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • Brand: Unbranded/Generic
  • All returns accepted: Returns Accepted
  • MPN: Does Not Apply

    Description

    K24 10-120L / MIN turbo electronic flowmeter Diesel fuel Methanol Urea Precision
    K24 internal thread
    Flowmeter manual
    Outline
    The modular design of the product control panel , with a full-featured , simple structure, convenient operation .
    Can be widely used in petroleum, chemical, pharmaceutical, transportation, food to be industrial and commercial .
    I.
    Technical Parameters
    Media
    Diesel oil, urea, kerosene, chemicals , gasoline
    Import and export
    1"
    Measurement accuracy
    ± 1%
    Repeatability
    ± 0.5%
    Maximum working pressure
    20BAR
    Operating Voltage
    3V(2*AA,but no battery inclued)
    Standby time
    2
    Year
    Flow Range
    10-120L / MIN
    Single counting
    0.00-9999.9
    The total cumulative number
    0.00-999999.9
    Unit of Measure
    Liter
    / L
    , Gallon
    / GAL
    , Pint
    / PTS
    , Quart
    / QTS
    Single measurement cleared
    RESET
    II.
    Units of measurement settings
    In standby mode , or raise the amount of the current display state , press
    RESET + MENU
    Bond
    2
    Seconds. Entering the unit conversion settings , such as screen as significant
    L
    Press
    RESET
    Button , followed by
    LTR

    GAL

    PT

    QT

    L
    Select the unit of measurement , while the cumulative amount raised after the display in accordance with the current measurement units conversion. Press
    MENU
    Bond
    1
    Seconds to exit the unit conversion settings.
    III.
    Can reset the cumulative amount cleared filling
    Long press
    RESET
    Key,
    LCD
    Fit as significant , depending on the end after waiting the full screen display , release
    RESET
    Button , then you can reset the cumulative amount of the filling amount with the current filling cleared .
    Five .
    Error coefficient and the total cumulative inquiry
    In standby mode, press
    MENU + RESET
    Key,
    LCD
    The row of numbers as significant error coefficient , the lower the total cumulative significantly depending on traffic.
    VI. Calibration error coefficient
    In standby mode , or raise the amount of the current display status , press
    MENU
    Button
    3
    Seconds to enter the calibration coefficient error state. Displays
    Cal USE
    Press
    MENU
    Button to select the number, then press
    RESET
    Key , digitally adjusted. Standard Coefficient
    1.000
    , Transferred
    1.100
    , A difference
    10L
    The higher the number , the less oil , the smaller the number , the more oil. After adjustment Press
    MENU
    Key to perform exit.
    Seven. Care and Maintenance
    When the battery voltage is too low ,
    LCD
    Battery symbol appears on the display screen to remind users to replace the battery.
    Battery life is too short can cause the battery during operation due to leakage caused by damage to the meter. This meter is designed standby life is about
    2
    Years, but recommends that customers each year to replace the battery . Customers are advised to check once each year battery electrode , should be subject to rust promptly removed. When long time without using the meter , the battery should be out .
    Instruction Manual for K24 Flow Meter
    Introduction
    The control panel of K 24 Flow meter adopts the concept of modular design, with features of complete function, simple construction, easy operation, etc, which is widely used in petroleum, chemistry, medicine, traffic, food and commercial industry.
    1. TECHNICAL DATA
    Medium
    Diesel, urea, kerosene,chemicals, gasoline
    outlet&inlet size
    1"
    measuring accuracy
    ±1%
    repeatability
    ±0.5%
    Max working pressure
    20BAR
    working voltage
    2.3-3.3V
    standby time
    2 years
    flow-rate range
    10-120L/MIN
    single count
    0.00-999.9
    total count
    0.00-999999.9
    measurement unit
    L,GAL,PTS,QTS
    single measurement reset
    RESET
    2. SET OF MEASUREMENT UNIT
    Under the state of standby or current charging display, press the button of MENU and RESET at the same time for 5 seconds. Enter the setting of unit conversion and press the RESET button, choose the measurement unit in turn according to the order of  LTR→GAL→PT→QT→LTR, meanwhile the accumulated charging quantity will be displayed based on the conversion of the current measurement unit conversion. Then press the MENU button for 3 seconds to quit the unit conversion setting.
    3. Error Coefficient Calibration
    Under the state of standby or current charging display, press the button of MENU for 3 seconds, entering the state of error coefficient calibration. Meanwhile when the first digital blinking displays, press the MENU button, then numeric shift (blinking digital displacement), press the RESET button, modify the current blinking figure, from 0 to 9 in turn, then back to 0. The oil pump capacity is less when the digital is increased; vice versa. Press the button MENU for 3 seconds to quit the error coefficient calibration. Back to the state of current charging quantity,and display it as reset. After the error coefficient calibration, demarcate it when there is new measuring pulse input. The range of  the error coefficient calibration is from 0.1000 to 9.9999. Press the button of MENU and RESET at the same time to check the coefficient and total accumulated figure.
    4. EXAMPLE OF Error Coefficient Adjustment
    When the original figure is 1.000, it will display as 100 L oil, the actual oil pump capacity is also 100 L. In case the user wants to reduce 2 L oil, then press the button of MENU for 3 seconds, adjust it to 1.020 according to the Error coefficient Calibration. Then the oil pump capacity will be 98 L. For 96 L, adjust it to 1.040; visa versa.
    1) Battery Low Prompt
    When the voltage of battery is between 2.2 v to 2.4 v, it will display as LBAT, to remind the user to replace the battery.
    5. Maintenance and Preservation
    This flow meter needs the battery with life span of at least 9,000 hours (1 year) as the power supply. The short battery life will lead to the battery leakage during working and result in the damage of the flow meter. The standby life of this flow meter is designed as 2 years. Battery replacement every one year is recommended. In case the LCD display becomes dim or the Lbat occurs, it is time to replace the battery. We recommend the users to check the Battery electrode to clear the rusting in case. Take out the battery if the flow meter is not used for a long time.
    come with
    1x k24 flowmeter
    shipping & payment
    * you will get it in 10-20 working days by standard airmail shipping from Hong Kong Post.
    * Only paypal accapted.it is fast ,easy & safe way.
    Contact us:
    * If you have any request please don't hesitate to contact us at first time,we will help you and solve your issue within 24 hours.
    * All emails will be answered within 1 business day. If you do not receive our reply, please kindly re-sent your email and we will reply you as soon as possible.
    * Warranty services are for replacements only,any problem please kindly email us frist,we will accept your advise & request.
    DO NOT DUPLICATE OR COPY! Template Made By: ©
    InkFrog.com
    Auction Templates, Logos, Store fronts and more!
    inkfrog terapeak