-40%

New Blancett 316SS Carbide Turbine Flow Meter 5000 PSI 400 GPM 2" NPT B111-120

$ 211.17

Availability: 100 in stock
  • Item must be returned within: 30 Days
  • Agency Compliance: UL, CSA, MET LABS
  • Rotor Material: CD4MCU Stainless Steel
  • Flow Meter Type: Turbine Flow Meter
  • Country/Region of Manufacture: United States
  • Port Threads: 2" NPT Female
  • All returns accepted: Returns Accepted
  • SELLER LOCATION: USA
  • Return shipping will be paid by: Buyer
  • Max. Pressure: 5000 PSI
  • Material: 316 Stainless Steel
  • Port Diameter: 2 in
  • Refund will be given as: Money Back
  • Fluid Temp. Range: -150 Degrees to 350F
  • Output: Frequency
  • Rotor Shaft Material: Tungsten Carbide
  • Accuracy: 1% of reading
  • Flow Range: 40 to 400 GPM (151.4 to 1514 Liters per Minute
  • Condition: These have never been used, but could need calibration, depending upon the fluid being metered, and the specifics of your particular application.
  • MPN: B111-120
  • Brand: Blancett

    Description

    4248SD6G.14.72
    New Blancett Model 1100, 316 Stainless Steel Body / Carbide Rotor Shaft, Turbine Flow Meter, Flowmeter, 400 GPM 2" NPT, Part Number B111-120.  Each bid quantity is for One (1) Flow Meter.  You may bid / buy any number, up to the total quantity available above.
    These were purchased at an industrial sale earlier this year, and they are brand new. They have never been used, but could need calibration, depending upon the fluid being metered, and the specifics of your particular application. No box or literature with them, but literature is available from the manufacturer online.
    According to the manufacturer
    :
    DESCRIPTION
    The Model 1100 turbine flow meter is designed to withstand the demands of the most rigorous flow measurement applications. Originally developed for the secondary oil recovery market, the Model 1100 flow meter is an ideal meter for liquid flow measurement on or off the oil field.
    The meter features a rugged 316 stainless steel housing and rotor support assemblies, CD4MCU stainless steel rotor, and abrasive-resistant tungsten carbide rotor shaft and journal bearings.The Model 1100 maintains measurement accuracy and mechanical integrity in the corrosive and abrasive fluids commonly found in oil field water flood projects and many industrial applications.
    When paired with a Blancett flow monitor, the Model 1100 turbine meter meets a wide range of measurement requirements. This makes it ideal for applications such as pipelines, production/injection fields, in-situ mining operations, offshore facilities, and other industrial applications.
    FEATURES
    • Offers accurate and repeatable flow measurement
    • Cost-effective solution for turbine flow meter applications
    • Rugged 316 stainless steel construction offers long service life in severe operating environments
    • Available in NPT
    • NIST traceable calibration
    • Installation in pipe size 2 in. Can integrate electronically with a Blancett flow monitor
    • K-factor Scaler, or the F to I/F to V Intelligent Converter Field replaceable repair kits allow for turbine replacement without loss of accuracy
    INSTALLATION
    The Model 1100 turbine meter is simple to install and service. It operates in any orientation (horizontal to vertical) as long as the “flow direction” arrow is aligned in the same direction as the actual line flow. For optimum performance, the flow meter should be installed with a minimum of 10 diameters upstream straight pipe length and 5 diameters downstream straight pipe length.
    OPERATING PRINCIPLE
    Fluid entering the meter passes through the inlet flow straightener which reduces its turbulent flow pattern and improves the fluid’s velocity profile. Fluid then passes through the turbine, causing it to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field at the base of the transducer, an AC voltage pulse is generated in the pickup coil. These pulses produce an output frequency proportional to the volumetric flow through the meter.
    K-FACTOR
    The K-factor represents the number of output pulses transmitted per gallon of fluid passing through the turbine meter. Each turbine has a unique K-factor. However, turbine meters are not functionally consistent throughout the full flow range of the meter. There are several forms of friction inherent in the turbine meters that retard the rotational movement of the turbine rotor. These frictional forces include: magnetic drag, created by electromagnetic forces of pickup transducers; mechanical drag, due to bearing friction; and viscous drag, produced by flowing fluid. As flow increases, the frictional forces are minimized and the free-wheeling motion of the turbine rotor becomes more linear (proportional to flow). The K-factor becomes relatively constant and the linear throughout the balance of the linear flow range. This is approximately a 10:1 turndown ratio from the maximum flow rate down to the minimum flow rate.
    Blancett B111-120 Specifications
    Max. Pressure (PSI): 5000
    Flow Material: Water, Low Viscosity Fluids
    Max. Viscosity (SUS): 150
    Max. Viscosity (SSU): 400
    Flow Range: 40 to 400 GPM (151.4 to 1514 Liters per Minute)
    Length (In.): 10"
    Ports: 2" NPT Female
    Housing Material: 316 Stainless Steel
    Rotor Material: CD4MCU Stainless Steel
    Rotor Shaft Material: Tungsten Carbide
    Wetted Materials: 316 Stainless Steel, Tungsten Carbide, CD4MCU Stainless
    Pressure Drop - 100% Flow (PSI): 9.0 psi
    Accuracy (%): 1% of reading
    Fluid Temp. Range: -150 Degrees to 350F
    Agency Compliance: UL, CSA, MET LABS
    Output: Frequency
    Type: Turbine
    Connection Size: 2 in
    Pulses per Gallon: 52
    Country of Origin: United States